Product Details:
Introduction of BT-8000C
Quick Details
Type:Blood Testing Equipments
Brand Name:yonker or OEM
Place of Origin:Jiangsu, China (Mainland)
Model Number:BT-8000C
Color:White
screen size:7 inch 8 inch 15 inch Optional
Option:2-IBP, ETCO2,built-in recorder, touch screen
Application scope:adult or infant
Company Type:manufacturer
Brand:yonker or OEM
Application:ICU, CCU, OR
Power supply:AC & bulit-in lithuim battery
Support Solution:wall mount, mobile trolley
Features:
12.1” color TFT screen
Humanized design with luminous buttons
One-button-switch for 8 user interfaces
Max 9 waveforms display simultaneously
Max 720H trend review, 2880 sets NIBP data storage
Dual visual alarm lights, 3 levels sound-light alarm system
Arrhythmia analysis, ST analysis, OXY-CRG analysis
Nurse call function; Pulse pitch modulation
Anti electrosurgical unit, anti defibrillation, anti interference
Various extensible functions including VGA/ SYNC outputs
Built-in chargeable lithium battery, maximum 2H use
Wire/ wireless to Central Monitoring System
Suitable for common ward, operating room etc.
Standard configuration:
ECG, HR, PR, SpO2, ST analysis,
RESP*2 (RA-LL impedance and nasal cavity),
NIBP (with venous punch),
TEMP*2(surface and rectal type),
Drug dose calculation.
Optional configuration:
Wireless connection, Recorder and ETCO2, 2-IBP
Temperature (surface and rectal)
Measurement range: 25.0–45.0C
Accuracy: +/-0.1C
Resolution:0.1C
response time: =<3 min.
ECG :
Input: 5 wires ECG cable
Lead section: I,II,III/ aVR, aVL, aVF/ V
Gain ( mm/mV ): 1/4 , 1/2 , 1 , 2 ,4
Frequency response :
Diagnosis 0.05 - 100Hz
Monitor 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed(mm/sec): 12.5, 25, 50
Heart rate range: 30-254 BPM
Heart rate accuracy: +/- 1%
ST segment deviation analysis: -0.8-+0.8mV
ST accuracy: +/-0.02mv
Respiration Rate :
( RALL impedance and nasal cavity)
Measurement range: 0 - 120 BPM(adult )
Accuracy: +/-1 BPM or 5%
Resolution: 1 BPM
---Power requirements :
Input: 98 - 260 V AC, 50/60Hz
Consumption: =< 80VA
---Environment :
Operation Storage
Temperature 0.5 - 40 C -20 - 50 C Relative humidity =< 80%
*----Pulse Rate:
SPO2 measurement range: 0 - 100%
Resolution:1%
Pulse measurement range: 30- 254BPM
Accuracy: +/- 2 %
Resolution: 1 BPM
----NIBP (Non-invasive blood pressure)
Measurement type : adult, pediatric, neonatal
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Accuracy : +/- 0.4 kPa or 5%
Resolution: 0.1 kPa
Protection: over pressure
*----IBP(Invasive blood pressure)
(with venous punch)
(Option)
Measurement range:
-1.3~40kPa (-10~300mmHg)
Channel: 2 channel
Transducer sensitivity: 5MV/V/mmHg
Unit display: KPa or mmHg selectable
*----ETCO2 (side stream type) (Option)
Measurement range:
0-10 % (ins CO2 and et CO2)
Accuracy:
+/- 2 mm Hg (< 5 % Measurement value)
10 % (> 5 % Measurement value)
Response time: 180 Ms =< 90%
Safety standard: IEC 60601-1
Quality System : ISO13485: 2003